Requirements

RIC Self-Check (Flow #1)

Status

to be tested

Call flow diagram 


RIC Self-Check SMO O-RAN RIC O-RAN Managed Function (MF) «OAM»O1 «OAM»O1 «NONRTRIC»Non-RT RIC «NONRTRIC»Non-RT RIC «RIC»A1 MED «RIC»A1 MED «RIC»O1 TERM «RIC»O1 TERM «RIC»HealthCk Function «RIC»HealthCk Function «RIC»Platform Modules «RIC»Platform Modules «RICAPP»xAPPs «RICAPP»xAPPs «RIC»E2 TERM «RIC»E2 TERM «MF»Managed Function «MF»Managed Function MF = O-CU, O-DU Alarms from individual RIC Platform Modules and xAPPs Note: Apart from Health-Checks, a platform module or xAPP may generate an alarm (orits clearing) when it encounters a failure/error (e.g., failure to reach another module) 1Platform Module Alarm/Clear 2«O1VES» Alarm or Clear 3xAPP Alarm/Clear 4«O1VES» Alarm or Clear RIC Self-Checks @ Regular Intervals Support HealthCheck Telemetry (FM, Heartbeat, PM) RIC Self-Checks Initiated loop for each Platform Module 5Perform HealthCheck Support Platform Module HealthCheck 6HealthCheck Status 7Platform Module Alarm/Clear 8«O1VES» Alarm or Clear loop for each xAPP instance deployed 9Perform HealthCheck 10HealthCheck Status Support xAPP HealthCheck 11xAPP Alarm/Clear 12«O1VES» Alarm or Clear 13«E2» keep-alive Support E2 Test Message Processing 14«E2» missed heartbeat 15E2 Alarm/Clear 16«O1VES» Alarm or Clear 17Log HC results & updatealarm-list in yang model Support Alarm Retrieval from SMO, Dashboard


Delivery Status



OTFOAMNONRTRICRICPRICAPPO-DUTest ResultNotes
Alarms from individual RICP Modules and xApps1. Platform Module Clarm/Clear (RICP.O1 -> OAM)







2. <<O1VES>> Alarm or Clear(RICP.O1 -> OAM)







3. xApp Alarm/Clear (RICAPP -> RICP.O1)







4. <<O1VES>> Alarm or Clear(RICP.O1 -> OAM)







RIC Self-checks @Regular Intervals5. Perform Healthcheck (RICP.O1 -> RICP.*)







6. Healthcheck Status (RICP components -> RICP.O1)







7. Platform Module Alarm/Clear (RICP.O1 -> RICP.O1)







8. <<O1VES>> Alarm or Clear(RICP.O1 -> OAM)







9. Perform Healghcheck (RICP.O1 -> RICAPP components)







10. Healthcheck Status (RICP components -> RICP.O1)







11. xApp Alarm/Clear






RICP: No alarm defined, may test manually with artificial alarm
12. <<O1VES>> Alarm or Clear(RICP.O1 -> OAM)







13. <E2> Alive (O-DU High -> RICP.E2T)






Use sctp keep alive, E2 Setup/response completed
14. <<E2>> Missing heartbeat (RICP.E2T to RICP.O1)







15. E2 Alarm/Clear (RICP.O1 -> RICP.O1)







16. <<O1VES>> Alarm or Clear(RICP.O1 -> OAM)







17. Log HC results and update alarm list in yang model






RICP: Logging implemented, not alarming

Test Manual

  • No labels